Parameter | Specification |
|---|---|
| Mating Cycles | >5,000 cycles |
| Humidity | Up to 95% RH at 60°C |
| Temperature Range | -55°C to +145°C |
| Vibration | 10–2,000 Hz; acceleration: 147 m/s²; contact discontinuity: ≤1 μs |
| Shock | Acceleration: 490 m/s²; contact discontinuity: ≤1 μs |
| Salt Spray Resistance | Pearl chrome: 72 h; black nickel: 96 h; 316L stainless steel: 1,000 h |
| Ingress Protection Rating | IP68, waterproof and dustproof |


1)Feed the cable through the cable boot ⑧, rear nut ⑦, cable clamp ⑥, sealing ring ⑤, and retaining ring ④ in sequence. Then solder the conductors to the insulator assembly ② according to the specified wiring sequence.
2)Fit grounding plates A/B ③ onto the soldered insulator assembly ②. Make sure the projection on the insulator assembly ② aligns with the notch in the grounding plates ③. Then slide the retaining ring ④, sealing ring ⑤, and cable clamp ⑥ into their proper positions on the cable.
3)Insert the assembled cable clamp ⑥, sealing ring ⑤, retaining ring ④, grounding plates A/B ③, and insulator assembly ② into the plug housing assembly ①.
4)Screw the rear nut ⑦ onto the plug housing assembly ① and tighten it securely.
5)After confirming that the assembly passes the dielectric withstand voltage, insulation resistance, and cable flex tests, fit the cable boot ⑧ over the corresponding shoulder on the rear nut ⑦.
Short-Body Plug Assembly Instructions

1)Feed the cable through the rear nut ⑤ and cable clamp ④ in sequence. Then solder the conductors to the insulator assembly ② according to the specified wiring sequence.
2)Fit the grounding plate ③ onto the soldered insulator assembly ②. Make sure the projection on the insulator assembly ② aligns with the notch in the grounding plate ③. Then slide the cable clamp ④ into its proper position on the cable.
3)Insert the assembled cable clamp ④, insulator assembly ②, and grounding plate ③ into the plug housing assembly ①.
Screw the rear nut ⑤ onto the plug housing assembly ① and tighten it securely.
4)After confirming that the assembly passes the dielectric withstand voltage, insulation resistance, and cable flex tests, place it in the molding machine for final overmolding.
Cable Harness Preparation

✦ The cable outer diameter must match the cable clamp size.
✦ The conductor size must be compatible with the contact termination diameter.
✦ For lead-free soldering, set the soldering iron temperature to approximately 380°C.
✦ Keep the soldering time for each conductor under 1 second.
✦ After soldering, insulate each conductor with heat-shrink tubing.
✦ Protect the contacts and insulator from damage during soldering.