Cross-sectional view of the B Series fixed receptacle and straight plug, showing the internal structure and key components.
Parameter | Specification |
|---|---|
| Mating cycles | More than 5,000 |
| Humidity | Up to 95% RH at 60℃ |
| Operating temperature | -45℃ to +125℃ |
| Vibration | 10–2,000 Hz, 15 g |
| Mechanical shock | 100 g, 6 ms |
| Salt spray resistance | More than 72 hours |
| Ingress protection | IP50 |

Exploded view of the B Series plug, showing the component sequence and key alignment points for cable assembly.

1)Pass the cable through the strain-relief boot ①, rear nut ②, and cable collet ③ in sequence.
2)Solder the conductors to the contact assembly ⑤ in the specified order.
3)Fit the two-piece retaining ring ④ onto the soldered contact assembly. Ensure that the window in the retaining ring aligns with the corresponding projection on the contact assembly.
4)Position the cable collet ③ correctly on the cable. Ensure that the projection on the cable collet aligns with the groove in the retaining ring ④.
Insert the contact assembly ⑤, retaining ring ④, and cable collet ③ into the plug shell assembly ⑥ in sequence. Ensure that the projection on the retaining ring aligns with the corresponding internal notch in the plug shell assembly.
5)Tighten the rear nut ② onto the plug shell assembly ⑥.
6)Fit the strain-relief boot ① over the corresponding shoulder of the rear nut ②.

Cable preparation dimensions for solder termination of B Series straight and L-Series right-angle plugs.
✦ Match the cable outside diameter to the specified cable collet size.
✦ Match the conductor size to the contact termination diameter.
✦ For lead-free soldering, set the soldering iron temperature to approximately 380°C.
✦ Keep the soldering time below one second per contact.
✦ Insulate each soldered conductor with heat-shrink tubing.
✦ Protect the contacts and insulator from damage during soldering.